Jean Müller
KETO-00
160A
37 available

Jean Müller · BMS and protection
250A
Add the product to your quote and send the request. Within 1–2 working days we'll email you the final price, delivery included.
An Italian company selling batteries, inverters and solar equipment since 2015. Registered office in Sigillo (Perugia), VAT IT03894170541.
About usNew, genuine Jean Müller products with the full manufacturer's warranty and all their documentation.
The KETO-1 is the size 1 Jean Müller NH fuse switch-disconnector, for battery systems whose current is too high for size 00. It is rated 250A and 690V AC; in DC it is rated 250V as a single pole and 440V in the three-pole version (DC-21B 440V/250A), with 120kA conditional short-circuit current with gG fuse-links and 8.6kA for 1s short-time withstand. That makes it a fit, for example, for a 51.2V battery stack delivering 200A or more. Opening the cover isolates all poles and removes the fuse-links. The body is 184mm wide, with M10 flat terminals for cable lugs up to 150mm², tightened to 30–35Nm. NH size 1 fuse-links are ordered separately.
A lithium battery can deliver a very high short-circuit current, so the cable between battery and inverter needs a fuse able to interrupt it and a way to isolate the battery for maintenance. A KETO fuse switch-disconnector does both: NH fuse-links sit in the switching cover, and lifting the cover opens the circuit and takes the fuse-links out of the current path, so batteries, cables and inverter can be worked on safely.
Jean Müller, based in Eltville, Germany, builds the KETO range to IEC/DIN EN 60947-3 for NH fuse-links to DIN VDE 0636-2. The range covers five sizes, from KETO-000 (125A) to KETO-3 (630A); for battery circuits of low-voltage home and small commercial systems the KETO-00 and KETO-1 are the usual choices.
The KETO-00 takes size 000 and 00 fuse-links and is rated 160A, 690V AC and 250V DC (DC-22B 250V/160A), with 5kA for 1s short-time withstand. It is 106mm wide with a 195mm system height and has M8 flat terminals for cable lugs up to 95mm².
The KETO-1 takes size 1 fuse-links and is rated 250A; in DC it is rated 250V per single pole and 440V for the three-pole device (DC-21B 440V/250A), with 8.6kA for 1s short-time withstand. It is 184mm wide with a 300mm system height and has M10 flat terminals for cable lugs up to 150mm², tightened to 30–35Nm. Both sizes have 8kV rated impulse withstand voltage and 120kA conditional short-circuit current at 500V with gG fuse-links.
The fuse rating sets the protection level and must be above the battery's maximum continuous current and within the current rating of the cables; the switch-disconnector must be rated at least for the fuse current and the system DC voltage. A 51.2V battery delivering up to about 100A fits a KETO-00 with 100A or 125A fuse-links, while stacks delivering 200A or more call for the KETO-1. Check also that the fuse-links themselves are rated for the DC voltage of the battery.
SolarGear offers the bodies on their own and KETO-00 sets complete with two NH00 fuse-links of 80A, 100A or 125A, one for the positive and one for the negative conductor.
KETO devices are mounted on a baseplate in vertical or horizontal position; KETO-000, -00 and -1 can also be fitted on two parallel DIN rails. In operation the degree of protection is IP20, and IP2XC on the front side with terminal and side covers fitted. Ambient temperature range is -25°C to +70°C, with reduced current above 35°C, up to 2000m altitude. Jean Müller asks for a minimum distance to earthed conductive parts of 20mm at the sides and 50mm above. A locking device for a padlock with up to 6mm shackle can be retrofitted to prevent unauthorised switching. Installation must be carried out by a qualified electrician.
Not with the KETO-00 and KETO-1 bodies. The KETO-00 sets are supplied with two NH00 fuse-links of 80A, 100A or 125A.
No. Jean Müller rates the KETO-00 for 250V DC. High-voltage batteries of 300V or more need devices rated for that DC voltage; the three-pole KETO-1 is rated 440V DC.
It depends on the current. Up to 160A the KETO-00 is enough; for higher currents, such as large 51.2V stacks delivering 200A or more, use the KETO-1, rated 250A.
KETO devices are load-break switches with utilization categories up to DC-22B 250V for size 00 and DC-21B 440V for size 1, but the safe practice is to stop charging and discharging from the inverter before opening the battery circuit.

Jean Müller
160A
37 available

Jean Müller
80A
5 available

Jean Müller
100A
13 available

Jean Müller
125A
Available to order

Redarc
100A12V
Available — quantity not tracked

Redarc
100A12V
Available — quantity not tracked

Deye
250A51.2V
Available — quantity not tracked

Deye
50A
Available — quantity not tracked
Email updates for installers and people planning a PV or storage system. Pick your topics: no spam, unsubscribe in one click.