Haier
NL1P-3.6KA2/H
3.68kWSingle-phase48V
5 available

Haier · Hybrid inverter
3kWSingle-phase48V
Add the product to your quote and send the request: we reply by email within 1–2 working days with the final price delivered to your address.
An Italian company selling batteries, inverters and solar equipment since 2015. Registered office in Sigillo (Perugia), VAT IT03894170541.
Who we areNew, original Haier products with full manufacturer warranty, supplied with their documentation.
The NL1P-3KA2/H is the 3kW model of Haier's NAHUI NL1P single-phase hybrid inverters. It accepts up to 4.5kW of PV on two 16A MPP trackers (550V maximum) and charges or discharges a 48V lithium or lead-acid battery at up to 60A. The EPS port supplies 3kW to essential loads within 10ms of a grid failure and tolerates 150% overload for 10 seconds. The IP65 housing weighs 19kg.
The NL1P is a non-isolated single-phase hybrid inverter from NAHUI, Haier's renewable energy platform. Two MPP trackers rated 16A cover 80–500V with a 550V maximum, and the maximum DC input is 1.5 times the AC rating, for example 9kW on the 6kW model. The battery port takes 48V lithium or lead-acid batteries (40–58V); lithium charging adapts to the battery BMS through CAN or RS485, and current ranges from 60A on the 3kW model to 120A on the 6kW model.
Three work modes are available: self-consumption, peak shift and battery priority, with an advanced mode that gives priority to feeding in or to charging. Up to six time-of-use slots define when the grid may charge the battery to a target SOC, and a grid power limit can be set.
When the grid fails, the EPS/load port supplies the rated power within 10ms and tolerates 110% for 60 seconds, 120% for 30 seconds and 150% for 10 seconds. The manual notes that with the Italian grid standard selected, the transfer from grid to off-grid needs a 500ms delay. A built-in CEI 0-21 self-test (auto test) is provided for installations in Italy.
The IP65 housing measures 454.5×467×200mm, weighs 19kg and is naturally cooled, with noise below 35dB and standby consumption below 15W. The manual specifies 300mm free space left and right, 500mm above and below and 1000mm in front. Grid connection standards listed are EN 50549-1, G98, G99 and CEI 0-21:2022.
Up to four inverters can work in parallel on a shared battery, connected through CAN parallel ports with CAT6 cables; all units need the same software version, and slaves follow the work mode of the master. Three units can also be grouped into a three-phase system. A CT is used to measure grid power at the connection point.
A colour display shows PV, grid, battery and load data and gives access to system, battery and parallel settings. A Wi-Fi dongle links the inverter to the NAHUI apps, and RS485, CAN and DRM ports are available for the BMS, external devices and demand response.
48V lithium batteries with CAN or RS485 BMS communication, or lead-acid batteries, within a 40–58V window. The maximum charge voltage is 58V.
Up to four, sharing the same battery bank. Three units can also be configured as a three-phase group.
No. The manual states that with the Italian grid standard selected, a 500ms delay is needed when the inverter moves from grid to off-grid operation.
The maximum DC input power is 1.5 times the AC rating: 4.5kW on the 3kW model up to 9kW on the 6kW model, over two MPPTs of 16A.

Haier
3.68kWSingle-phase48V
5 available

Haier
5kWSingle-phase48V
5 available

Haier
6kWSingle-phase48V
5 available

Haier
3kWSingle-phase48V
5 available

Haier
3kWSingle-phaseHV
5 available

Hoymiles
3kWSingle-phase48V
Available — quantity not tracked

SolaX
3kWSingle-phaseHV
20 available
Email updates for installers and people planning a PV or storage system. Pick your topics: no spam, unsubscribe in one click.