Fronius
Tauro 50-3-D
50kWThree-phase
20 available

Fronius · String inverter
50kWThree-phase
Add the product to your quote and send the request: we reply by email within 1–2 working days with the final price delivered to your address.
An Italian company selling batteries, inverters and solar equipment since 2015. Registered office in Sigillo (Perugia), VAT IT03894170541.
Who we areNew, original Fronius products with full manufacturer warranty, supplied with their documentation.
The Tauro ECO 50-3-P combines the single-tracker Tauro ECO design with precombined DC inputs: two inputs, PV1 and PV2, take cable lugs or V clamps for 25–95mm² conductors coming from external combiner boxes with string fuses. The MPP window is 580–930V with 650V start-up, input current reaches 87.5A and the PV array may be up to 75kWp. Maximum efficiency is 98.5% and European efficiency 98.2%, in a 74kg IP65 housing rated for -40 to +65°C.
Tauro is the Fronius platform for large commercial string systems, built in a 755×1109×346mm double-wall housing with active cooling and IP65 protection for -40 to +65°C. Tauro 50-3 has three MPP trackers and a 400–870V MPP range for arrays with several orientations. Tauro ECO 50, 99 and 100 use a single tracker with a 580–930V window and 650V start-up voltage, intended for large uniform fields with long strings.
Every model comes in two DC versions. The direct (D) version takes strings straight on Stäubli MC4 connectors through integrated 20A or 30A string fuses, so no external combiner box is needed. The precombined (P) version has one DC input per tracker or input group, with cable lugs or V clamps for 25–95mm² aluminium or copper conductors, and the strings are fused in an external combiner box.
Maximum efficiency is 98.5% on every model, with European efficiency of 98.3% for Tauro 50 and 98.2% for Tauro ECO. Type 1+2 DC and AC surge protection is integrated, with type 2 as an option, together with DC disconnectors, an RCMU and insulation monitoring. Fronius Arc Guard is available as an option on D versions with 20A fuses. Fronius permits 50% oversizing, which gives 75kWp on the 50kW models and 150kWp on ECO 99 and 100.
The inverter mounts vertically on a wall or post, or horizontally on a flat roof at a minimum 3° tilt, where the optional floor racks are recommended. Fronius recommends 80A AC overcurrent protection for a single 50kW unit. A residual current device is not generally required; if one is fitted it must be type B with at least 1,000mA. AC conductors of 35–240mm² (70–240mm² on ECO 99/100) in aluminium or copper are accepted.
With the AC daisy chain version, the AC cable runs from one Tauro to the next up to 200kW in total, with 160A to 355A recommended protection depending on the chained power. TT (with N–PE voltage below 30V), TN-S, TN-C and TN-C-S earthing systems are permitted, IT is not. Fronius excludes installation in stables, feed stores and areas with ammonia or corrosive gases.
An integrated data logger and web server connect each inverter directly to Fronius Solar.web over WLAN or Ethernet, in a star topology on multi-inverter sites. Modbus TCP SunSpec, the Solar API (JSON) and two RS485 ports for Modbus RTU SunSpec serve SCADA systems and the Fronius Smart Meter, which enables feed-in limitation. Six digital inputs and six I/Os handle ripple control receivers and load control, wired shutdown provides an emergency stop chain, and commissioning uses the Fronius Solar.start app.
The direct (D) version connects strings directly on MC4 connectors with integrated 20A or 30A string fuses. The precombined (P) version has one large DC input per tracker or input group for cables coming from an external combiner box, where the strings are fused.
Tauro 50 has three MPP trackers with a 400–870V range for arrays with different orientations. Tauro ECO 50 has a single tracker with a 580–930V range and 650V start-up voltage; Fronius recommends designing for at least 600V MPP voltage.
Fronius states there is no general requirement. If local rules call for one, it must be a type B device with a tripping current of at least 1,000mA.
Yes, with the AC daisy chain version the AC lead is looped from inverter to inverter up to 200kW in total. Fronius recommends 160A, 250A or 355A protection for 100, 150 or 200kW.
Fronius Arc Guard is optional and available only on the direct (D) versions with 20A string fuses. The precombined versions do not offer it.

Fronius
50kWThree-phase
20 available

Fronius
50kWThree-phase
20 available

Fronius
50kWThree-phase
20 available

SolarEdge
50kWThree-phase
Available — quantity not tracked

Solis
50kWThree-phase
Available to order

Deye
50kWThree-phase
2 available

SMA
50kWThree-phase
20 available
Email updates for installers and people planning a PV or storage system. Pick your topics: no spam, unsubscribe in one click.