Redarc
BSEN500
500A
Available — quantity not tracked

Eastron · Monitoring
100A
Add the product to your quote and send the request. Within 1–2 working days we'll email you the final price, delivery included.
An Italian company selling batteries, inverters and solar equipment since 2015. Registered office in Sigillo (Perugia), VAT IT03894170541.
About usNew, genuine Eastron products with the full manufacturer's warranty and all their documentation.
The SDM230-Modbus is a two-module DIN-rail energy meter for single-phase circuits up to 100A, connected directly without current transformers. It is MID certified (annexes B and D, class 1 for active energy) and measures voltage, current, frequency, power factor, active, reactive and apparent power and imported and exported energy, with four selectable ways of totalising kWh for PV and battery systems. Readings are available over RS485 Modbus RTU and two pulse outputs. Inverter makers use it for export limitation: Deye lists it for its single-phase string and low-voltage hybrid inverters, Solplanet for the ASW S-G2 series. Check the approved meter list of your inverter before ordering.
SDM230 meters are wired in series with a single-phase circuit of up to 100A and measure energy in both directions. They show voltage, current, frequency, power factor, active, reactive and apparent power, maximum demand and imported and exported active and reactive energy. Four modes define how the total kWh register combines import and export (import only, import plus export, export minus import, import minus export), which helps when the meter sits at the grid connection of a PV or battery system.
Eastron builds four versions: SDM230-Modbus with RS485 Modbus RTU and pulse outputs, SDM230-MBus with M-Bus to EN 13757-3, SDM230-Pulse with pulse outputs only and SDM230-2T, a dual-tariff version with Modbus. On the Modbus model, baud rate (1200–9600), parity, stop bits and address (1–247) are set from the front-panel menu, where communication parameters are password protected. Two passive pulse outputs, one configurable, give between 1 and 1000 pulses per kWh.
The meter occupies two DIN-rail modules (DIN 43880) and has cage terminals for cables up to 25mm². It is rated IP51 for indoor boards, -25°C to +55°C and altitudes up to 3000m. MID certification covers EN 50470-1 and EN 50470-3 class B, with EMC to EN 61326-1 and safety to EN 61010-1; class 1 accuracy is guaranteed from 0.5A upwards.
Several inverter manufacturers list the SDM230-Modbus in their manuals: Deye for its SUN-G04P1 single-phase string inverters and SG05LP1 low-voltage hybrids, Solplanet for its ASW S-G2 single-phase inverters. Each brand defines its own Modbus address and wiring to the meter port, so follow the inverter manual and confirm that your model lists this meter.
No. It is connected directly in the circuit and measures up to 100A.
The SDM230-Modbus, which communicates over RS485 Modbus RTU; check that the inverter manual lists it.
It is MID certified (annexes B and D) with class 1 accuracy for active energy.
Yes. Imported and exported energy are registered separately, and the total register can be set to one of four modes.

Redarc
500A
Available — quantity not tracked

Redarc
Battery state-of-charge display for the REDARC Smart Battery Monitor
Available — quantity not tracked

Redarc
4.3in RedVision control display for TVMS Rogue, TVMS Prime and Manager30
Available — quantity not tracked

Safiery
Battery Bluetooth radar level sensor for diesel tanks with reflector plate
Available — quantity not tracked
Email updates for installers and people planning a PV or storage system. Pick your topics: no spam, unsubscribe in one click.