
Solis
Solis-EPM3-5G-PRO
Export power manager for sites with several Solis inverters, IP65
16 available

Solis · Monitoring
Add the product to your quote and send the request. Within 1–2 working days we'll email you the final price, delivery included.
An Italian company selling batteries, inverters and solar equipment since 2015. Registered office in Sigillo (Perugia), VAT IT03894170541.
About usNew, genuine Solis products with the full manufacturer's warranty and all their documentation.
This kit pairs the Eastron SDM630MCT V2 three-phase meter with three split-core current transformers for Solis hybrid inverters. Solis lists the V2 meter, which works with 5A-secondary CTs, for the S6-EH3P(5-10)K-H, S6-EH3P(12-20)K-H, S6-EH3P(29.9-50)K-H, S6-EH3P(8-15)K02-NV-YD-L and S6-EA3P(5-10)K-NV-ND-H series; on the S6-EH3P(30-50)K-H the inverter identifies the Eastron meter automatically. It is the option when the grid connection point is too far for the CTs supplied with the inverter, as on the 30–50kW models whose CT cable is 4m and cannot be extended. The meter mounts on a DIN rail, has a backlit LCD and talks Modbus RTU over RS485; Eastron rates active energy at class 1.
A grid-connection meter measures the power flowing to and from the public grid and passes the reading to the inverter over RS485. A hybrid inverter uses it to decide when to charge or discharge the battery, and a grid-tied inverter uses it to limit export to a set value. The same data feeds the consumption view in SolisCloud, so household or site load can be followed alongside PV production.
Solis publishes a meter and CT compatibility guide that lists which meter goes with which inverter series. It warns that meters or CTs not in the list are not supported by Solis Service, and that some small grid-tied inverters accept either a meter or CT clamps, not both, so the inverter model should be checked before ordering.
The Acrel ACR10R-D16TE is a single-phase meter used with an external 120A:40mA CT on single-phase grid-tied inverters with a meter port and on single-phase hybrids such as the S5-EH1P(3-6)K-L and RHI-48ES series. The Acrel DTSD1352 with three 150A:5A CTs is the three-phase choice for Solis grid-tied string inverters, and is also listed for S6-EH1P(3-8)K-PLUS hybrids in parallel systems.
The Eastron SDM630MCT V2 works with 5A-secondary CTs and is listed for the three-phase hybrid series S6-EH3P(5-10)K-H, S6-EH3P(12-20)K-H, S6-EH3P(29.9-50)K-H, S6-EH3P(8-15)K02-NV-YD-L and S6-EA3P(5-10)K-NV-ND-H. Several of these hybrids also run on directly connected CTs, so the meter is optional where the CT cable length or a remote grid connection point makes it necessary.
Where one site has several three-phase PV inverters, the Solis-EPM3-5G-PRO measures the grid connection with its own meter and CTs and controls all inverters over RS485 with Modbus. Solis gives a power control accuracy of 1% of rated power, a control time of 5s, a failsafe function and remote firmware upgrades. It is listed as compatible with all Solis PV inverters and with RHI-3P(5-10)K-HVES-5G hybrids.
The EPM3-5G-PRO has an LCD display, an IP65 housing for indoor or outdoor mounting and draws less than 6W. Monitoring goes through an optional Solis Wi-Fi, 4G or LAN data logger plugged into the EPM. The Solis-EPM3-5G-PLUS does the same job on three-phase sites with a DTSD1352-C meter built in and integrated Wi-Fi and LAN, so no separate logger is needed; it draws less than 15W, and its 5A-secondary CTs are ordered separately.
Meters are wired at the grid connection point with the CTs on the incoming phase conductors, observing the CT direction and phase sequence. With 5A CTs the ratio must be entered in the meter: Solis gives a value of 30 for the 150A:5A CTs supplied with the DTSD1352. After installation, the meter type and its position, grid side or load side, are selected in the inverter settings.
No. Several S6 three-phase hybrids work with CTs connected directly to the inverter, and the S6-EH3P(29.9-50)K-H ships with three 300A/5A CTs. A meter is needed where Solis lists it for the inverter or where the CTs cannot reach the inverter.
Solis supports only the meters and CTs in its compatibility guide. With a different meter the inverter may not read the grid power correctly and Solis Service cannot provide support.
The EPM3-5G-PRO and EPM3-5G-PLUS are meant for sites with more than one three-phase PV inverter, where a single device has to limit the total export of all inverters at the grid connection point.
With the three 150A:5A CTs supplied, Solis states a ratio of 30 (150 divided by 5). Other 5A CTs use the same formula.

Solis
Export power manager for sites with several Solis inverters, IP65
16 available

Solis
Single-phase energy meter with 120A:40mA CT for Solis inverters
20 available

Solis
Three-phase energy meter with three 150A:5A CTs for Solis string inverters
65 available

Solis
Three-phase export power manager with built-in meter, Wi-Fi and LAN, IP65
Available — quantity not tracked

Solis
Dual-band Wi-Fi monitoring stick, 4-pin connector, IP65
186 available

Solis
Wi-Fi and LAN monitoring stick, 4-pin connector, IP65
96 available

Solis
Wi-Fi and LAN monitoring stick, USB connector, IP65
215 available

Solis
Commercial data logger, 4 RS485 ports and LAN, up to 60 devices
10 available
Email updates for installers and people planning a PV or storage system. Pick your topics: no spam, unsubscribe in one click.